Shah Electronics


Home

Profile

Products

Contact Us



Showcase Gallery


Home » Products » Current Transformer


Current Transformer

Our range of electronic energy meter C.T we have gained tremendous accolades in the market for their host of exclusive features. These electronic energy meter C.T are manufactured using qualitative materials sourced from trusted vendors. We offer these voltage electronic coils in different specifications.

Current Transformer
Energy Meter Coils


Energy Meter Coils

The Energy Meter Coils, also known as voltage electronic coils we manufacture are designed using latest technology and optimum quality raw material. These voltage electronic coils are available in different technical specifications and test details.
  • Phase Angle
  • Minimum Amplitude Error
  • Liner Linearity
  • Magnetic Stability
  • No Saturation Condition
  • International Meter Standards
  • Shah Electronics manufactures the C.T.s from 5 AMP to 200 AMP
  • Capacity with accuracy of class 0.5 & 0.2.





Current Transformer


Current Transformer

Item Code: Current-Transformer-Coils

A company with ISO - 9001 : 2008 Certified Production Process.

 

We support our customers to achieve best quality and performance with our high grade ferrite winding products.

 

All products Designed and Manufactured as per Customers Requirement with state of the art automatic winding machinery and cutting edge testing setup with Automatic Testing Equipments.

 

The Current Transformer Coils, we manufacture are designed using latest technology and optimum quality raw material. These Current Sensing coils are available in different technical specifications and test details.

  • Phase angle
  • Minimum amplitude error
  • Liner linearity
  • Magnetic stability
  • No saturation condition
  • International meter standards
  • Shah electronics manufactures the C.T.s from 5 AMP to 200 AMP
  • Capacity with accuracy of class 0.5 & 0.2.

Applications:-

  • Digital Energy Meters
  • Motor Current Sensing
  • Instrument Transformers 


Other Information

  • Production Capacity: 200000 pcs / month








2 AMP. Current Transformer


2 AMP. Current Transformer

Item Code: SET1606-550-2A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 0.1 Amp.
2) Maximum Primary Current (Imax) : 2 Amp.
3) Secondary Current : 3.6 mA.
4) Winding Ratio : 1:550
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 11 Ohms @ Vout = 40 mili Volts. Maximum Value: 29 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 60 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 6.7 X 17.5 X 8.2 / (With Dabbi)- 5 X 23 X 20

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








5 AMP. Current Transformer


5 AMP. Current Transformer

Item Code: SET2210-1200-5A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 0.1 Amp.
2) Maximum Primary Current (Imax) : 5 Amp.
3) Secondary Current : 4.2 mA.
4) Winding Ratio : 1:1200
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 120 Ohms @ Vout = 0.5 Volts. Maximum Value: 250 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 520 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 10.8 X 24.3 X 14 / (With Dabbi)- 6.5 X 29.5 X 26.5
*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








10 AMP. Current Transformer


10 AMP. Current Transformer

Item Code: SET2610-1200-10A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 1 Amp.
2) Maximum Primary Current (Imax) : 10 Amp.
3) Secondary Current : 8.3 mA.
4) Winding Ratio : 1:1200
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 120 Ohms @ Vout = 1 Volts. Maximum Value: 252 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 524 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 10.2 X 28 X 18 / (With Dabbi)- 8.4 X 35 X 21.5

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








20 AMP. Current Transformer


20 AMP. Current Transformer

Item Code: SET2106-2500-20A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 1 Amp.
2) Maximum Primary Current (Imax) : 20 Amp.
3) Secondary Current : 8 mA.
4) Winding Ratio : 1:2500
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 125 Ohms @ Vout = 1 Volts. Maximum Value: 440 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 917 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 10 X 28.5 X 23.3 / (With Dabbi)- 29.5 X 26.5 X 12

*Here Vct is considered as the CT secondary voltage signal required feed the AtoD converter and it assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








30 AMP. Current Transformer


30 AMP. Current Transformer

Item Code: SET2610-2500-30A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 5 Amp.
2) Maximum Primary Current (Imax) : 30 Amp.
3) Secondary Current : 12 mA.
4) Winding Ratio : 1:2500
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 75 Ohms @ Vout = 0.9 Volts. Maximum Value: 786 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 1637 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
14) Dimensions ( I.D. X O.D. X H in mm.) : (With Dabbi)- 8.4 X 30 X 21.5

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








40 Amp. Current Transformer


40 Amp. Current Transformer

Item Code: SET3112-5000-40A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 5 Amp.
2) Maximum Primary Current (Imax) : 40 Amp.
3) Secondary Current : 8 mA.
4) Winding Ratio : 1:5000
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 125 Ohms @ Vout = 1 Volts. Maximum Value: 1697 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 3535 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 13 X 36.5 X 17.8

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








60 AMP. Current Transformer


60 AMP. Current Transformer

Item Code: SET2615-2500-60A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 10 Amp.
2) Maximum Primary Current (Imax) : 60 Amp.
3) Secondary Current : 24 mA.
4) Winding Ratio : 1:2500
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 25 Ohms @ Vout = 0.6 Volts. Maximum Value: 1446 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 3011 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire
14) Dimensions ( I.D. X O.D. X H in mm.) : 9.84 X 29.2 X 18.2

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








80 Amp. Current Transformer


80 Amp. Current Transformer

Item Code: SET2X3106-2500-80A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 10 Amp.
2) Maximum Primary Current (Imax) : 80 Amp. 3) Secondary Current : 32 mA.
4) Winding Ratio : 1:2500
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 25 Ohms @ Vout = 0.8 Volts. Maximum Value: 817 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 1702 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 25.5 X 39 X 19 / (With Dabbi)- 9 X 39 X 22

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








100 Amp. Current Transformer


100 Amp. Current Transformer

Item Code: SET2x2610-2500-100A

· Features :

Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779

Ø Current Transformer with PC Housing for better insulation and environmental protection.

Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

· Applications:

Ø Energy Meters

Ø Electronic Circuit Breaker

Ø Current Sensors

Ø Motor Speed Controllers

· Specifications:

1) Basic Primary Current (Ib) : 10 Amp.

2) Maximum Primary Current (Imax) : 100 Amp.

3) Secondary Current : 40 mA.

4) Winding Ratio : 1:2500

5) Frequency : 50 Hz

6) Accuracy Class : 1.0

7) Recommended Burden Resistance (Ru) : 25 Ohms @ Vout = 1 Volts. Maximum Value: 1500 Ohms. (As per Eqn. R = Vct X N / Ip )*.

8) Recommended Burden Resistance (Ra) : Maximum Value: 3500 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.

9) Insulation – Pri & Sec : 5000V

10) Insulation – Pri,Sec & Earth : ≥ 1000 M

11) Operating & Storage Temp. : -40C ~ +85C

12) Humidity : ≤90%

13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi

14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 10.2 X 28.5 X 23.5

 

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter.

Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly

select at your discretion.



Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








200 Amp. Current Transformer


200 Amp. Current Transformer

Item Code: SET5811-6000-200A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 10 Amp.
2) Maximum Primary Current (Imax) : 200 Amp.
3) Secondary Current : 33.3 mA.
4) Winding Ratio : 1:6000
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 30 Ohms @ Vout = 1 Volts. Maximum Value: 1571 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 3273 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 32.5 X 64 X 24

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








300 AMP. Current Transformer


300 AMP. Current Transformer

Item Code: SET4511-2000-300A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Basic Primary Current (Ib) : 10 Amp.
2) Maximum Primary Current (Imax) : 300 Amp.
3) Secondary Current : 150 mA.
4) Winding Ratio : 1:2000
5) Frequency : 50 Hz
6) Accuracy Class : 1.0
7) Recommended Burden Resistance (Ru) : 6 Ohms @ Vout = 0.9 Volts. Maximum Value: 283 Ohms. (As per Eqn. R = Vct X N / Ip )*.
8) Recommended Burden Resistance (Ra) : Maximum Value: 590 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
9) Insulation – Pri & Sec : 5000V
10) Insulation – Pri,Sec & Earth : ≥ 1000 M
11) Operating & Storage Temp. : -40C ~ +85C
12) Humidity : ≤90%
13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi
14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 22.5 X 48.5 X 15.5 / (With Dabbi)- 54.5 X 62 X 20

*Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month








30 AMP. ELCB / RCCB / RCD Current Transformer


30 AMP. ELCB / RCCB / RCD Current Transformer

Item Code: SET2615-525-30A
· Features :
Ø Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
Ø Current Transformer with PC Housing for better insulation and environmental protection.
Ø Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
· Applications:
Ø Energy Meters
Ø Electronic Circuit Breaker
Ø Residual Current Circuit Breakers
Ø Earth Leakage Current Circuit Breaker
Ø Current Sensors
Ø Motor Speed Controllers
· Specifications:
1) Maximum Primary Current (IL , IN) : 30 Amp.
2) Winding Ratio : 1:525
3) Frequency : 50 Hz
4) Accuracy Class : 1.0
5) Sensitivity ( Ir ) : 7 mA.
6) Insulation – Pri & Sec : 5000V
7) Insulation – Pri,Sec & Earth : ≥ 1000 M
8) Operating & Storage Temp. : -40C ~ +85C
9) Humidity : ≤90%
10) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
11) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 7.7 X 29 X 18.3 / (With Dabbi)- 30.5 X 34.5 X 21.7

Other Information

  • Minimum Order Quantity: 100 Pieces
  • Production Capacity: 500000 per month












Contact Us
Shah Electronics
Mr. Hitesh Shah
A - 3, Manoharvilla, New Naroda, Nicol Road, Near Naroda Ca Nal, Nicol
Ahmedabad - 382325, Gujarat, India

Contact via E-mail



Home  |  Profile  |  Products  |  Site Map  |  Contact Us   |   Mobile Site

Member IndiaMART.com © Shah Electronics. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited