Send Email
Send SMS
Search
Shah Electronics


Current Transformer

Our range of electronic energy meter C.T we have gained tremendous accolades in the market for their host of exclusive features. These electronic energy meter C.T are manufactured using qualitative materials sourced from trusted vendors. We offer these voltage electronic coils in different specifications.

Energy Meter Coils

REQUEST CALLBACK

Energy Meter Coils
Ask for Price

Thanks for Contacting Us.

Product Details:
Minimum Order Quantity50 Unit
MaterialCopper

The Energy Meter Coils, also known as voltage electronic coils we manufacture are designed using latest technology and optimum quality raw material. These voltage electronic coils are available in different technical specifications and test details.
  • Phase Angle
  • Minimum Amplitude Error
  • Liner Linearity
  • Magnetic Stability
  • No Saturation Condition
  • International Meter Standards
  • Shah Electronics manufactures the C.T.s from 5 AMP to 200 AMP
  • Capacity with accuracy of class 0.5 & 0.2.
Yes! I am Interested

2 AMP. Current Transformer

REQUEST CALLBACK

2 AMP. Current Transformer
Ask for Price

Thanks for Contacting Us.

Product Details:
Minimum Order Quantity50 Unit
Brand/MakeShah Electronics
PhaseSingle Phase

We are the prominent organization of this domain engaged in offering a wide spectrum of 2 AMP Current Transformer. This transformer has a panel structure that looks attractive when mounted due to its round alms. Also, it has die-cast white powder coated body available in WH/WW color. In addition, this transformer is manufactured using quality materials and advanced technology. Our professionals utilize optimum grade materials and adhering to industry quality standards during fabrications.

Features:

  • Custom or on call designs are accepted
  • Easy to maintain
  • Resistance to heat and fire

Applications:

  • Energy Meters
  • Electronic Circuit Breaker

Specifications:

  • Secondary Current : 3.6 mA
  • Winding Ratio : 1:550
  • Frequency : 50 Hz
  • Accuracy Class : 1.0
  • Recommended Burden Resistance (Ru) : 11 Ohms @ Volt = 40 mili Volts

Additional Information:

  • Item Code: SET1606-550-2A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    5 AMP Current Transformer

    REQUEST CALLBACK

    5 AMP Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Rated Power (VA)22Watt +/- 10%
    Rated Voltage90 VAC to 450 VAC

    We feel proud to introduce ourselves as the leading organization in this domain, engaged in presenting an excellent grade of 5 AMP. Current Transformer. Due to its high volt range, the transformer is recommended to be used in all weather conditions. Further, the ambient temperature range of the transformer is 15 °C for storage temperature and maximum temperature it can sustain is 75 °C. At our manufacturing unit, our engineers have designed the transformer adhering to European industry standards and using heavy cast metal alloy.

    Features:

    • Better design and concept
    • Alluring design
    • Heavy duty

    Applications:

    • Energy Meters
    • Electronic Circuit Breaker

    Specifications:

    • Operating Voltage: 230VAC +/- 10%
    • Operating Frequency: 50 Hz +/- 4%
    • Input Current: 26 mA +/- 10%
    • Input Power: 3Watt +/- 10%
    • Output Power: 2.6Watt +/- 10%

    Additional Information:

  • Item Code: SET2210-1200-5A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    10 AMP Current Transformer

    REQUEST CALLBACK

    10 AMP Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Accuracy Class1
    Cooling TypeDry Type/Air Cooled
    Primary Current1 Amp
    Maximum Primary Current10 Amp
    Secondary Current8.3 mA
    Winding Ratio1:1200
    Frequency50 Hz
    Operating Temperature-40C ~ to +85 Degree C
    Humidity90%
    Dimension10.2 X 28 X 18 mm

    Features :

    • Designed and developed as per European Standards IEC: 62053-21 / IS: 13779
    • Current Transformer with PC Housing for better insulation and environmental protection
    • Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT


    Applications
    :

    • Energy Meters
    • Electronic Circuit Breaker
    • Current Sensors
    • Motor Speed Controllers


    Recommended Burden Resistance (Ru)
    : 120 Ohms @ Vout = 1 Volts. Maximum Value: 252 Ohms. (As per Eqn. R = Vct X N / Ip )*. 


    Recommended Burden Resistance (Ra
    ): Maximum Value: 524 Ohms. For Analog Interface using a bridge rectifier and bulk capacitor.


    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than the absolute maximum rating of an input pin of the AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.


    Additional Information:

  • Item Code: SET2610-1200-10A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    20 AMP Current Transformer

    REQUEST CALLBACK

    20 AMP Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Accuracy Class1.0
    CT Ratio1:2500
    Primary Current1 amp
    Maximum Primary Current20 Amp
    Secondary Current8 mA
    Winding Ratio1:2500
    Frequency50 Hz
    Humidity90%
    Mounting TypeSelf Flying Wire-Without Dabbi
    Dimension10 X 28.5 X 23.3 mm

    Features:
    • Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
    • Current Transformer with PC Housing for better insulation and environmental protection.
    • Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications
    :
    • Energy Meters
    • Electronic Circuit Breaker
    • Current Sensors
    • Motor Speed Controllers

    *Here Vct is considered as the CT secondary voltage signal required feed the AtoD converter and it assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Select at your discretion.

    Additional Information:

  • Item Code: SET2106-2500-20A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    30 AMP. Current Transformer

    REQUEST CALLBACK

    30 AMP. Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Input Voltage5000V
    PhaseSingle Phase

    Features :
    Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
    Current Transformer with PC Housing for better insulation and environmental protection.
    Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications:
    Energy Meters
    Electronic Circuit Breaker
    Current Sensors
    Motor Speed Controllers

    Specifications:
    1) Basic Primary Current (Ib) : 5 Amp.
    2) Maximum Primary Current (Imax) : 30 Amp.
    3) Secondary Current : 12 mA.
    4) Winding Ratio : 1:2500
    5) Frequency : 50 Hz
    6) Accuracy Class : 1.0
    7) Recommended Burden Resistance (Ru) : 75 Ohms @ Vout = 0.9 Volts. Maximum Value: 786 Ohms. (As per Eqn. R = Vct X N / Ip )*.
    8) Recommended Burden Resistance (Ra) : Maximum Value: 1637 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
    9) Insulation – Pri & Sec : 5000V
    10) Insulation – Pri,Sec & Earth : ≥ 1000 M
    11) Operating & Storage Temp. : -40C ~ +85C
    12) Humidity : ≤90%
    13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
    14) Dimensions ( I.D. X O.D. X H in mm.) : (With Dabbi)- 8.4 X 30 X 21.5

    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.


    Additional Information:

  • Item Code: SET2610-2500-30A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    40 Amp Current Transformer

    REQUEST CALLBACK

    40 Amp Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Secondary Current8 mA
    Basic Primary Current (Ib)5 Amp
    Frequency50 hz
    Storage Temp-40 to 85 Degree C
    HumidityLess than 90 %
    Dimensions13 X 36.5 X 17.8 mm
    Accuracy Class1 or 3
    Core TypeRing Core Type CT
    CT Ratio1:5000

    Features :
    • Designed and developed as per European Standards IEC: 62053-21 / IS: 13779
    • Current Transformer with PC Housing for better insulation and environmental protection.
    • Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.
    Applications:
    • Energy Meters
    • Electronic Circuit Breaker
    • Current Sensors
    • Motor Speed Controllers

    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than the absolute maximum rating of an input pin of the AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

    Additional Information:

  • Item Code: SET3112-5000-40A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    60 AMP. Current Transformer

    REQUEST CALLBACK

    60 AMP. Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Input Voltage5000V
    PhaseSingle Phase

    Features :
    Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
    Current Transformer with PC Housing for better insulation and environmental protection.
    Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications:
    Energy Meters
    Electronic Circuit Breaker
    Current Sensors
    Motor Speed Controllers

    Specifications:
    1) Basic Primary Current (Ib) : 10 Amp.
    2) Maximum Primary Current (Imax) : 60 Amp.
    3) Secondary Current : 24 mA.
    4) Winding Ratio : 1:2500
    5) Frequency : 50 Hz
    6) Accuracy Class : 1.0
    7) Recommended Burden Resistance (Ru) : 25 Ohms @ Vout = 0.6 Volts. Maximum Value: 1446 Ohms. (As per Eqn. R = Vct X N / Ip )*.
    8) Recommended Burden Resistance (Ra) : Maximum Value: 3011 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
    9) Insulation – Pri & Sec : 5000V
    10) Insulation – Pri,Sec & Earth : ≥ 1000 M
    11) Operating & Storage Temp. : -40C ~ +85C
    12) Humidity : ≤90%
    13) Mounting Type / Housing (Optional) : Self (Flying) Wire
    14) Dimensions ( I.D. X O.D. X H in mm.) : 9.84 X 29.2 X 18.2
    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

    Additional Information:

  • Item Code: SET2615-2500-60A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    80 Amp. Current Transformer

    REQUEST CALLBACK

    80 Amp. Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Cooling TypeOil Cooled
    Input Voltage5000V
    PhaseSingle Phase

    Features :
    Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
    Current Transformer with PC Housing for better insulation and environmental protection.
    Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications:
    Energy Meters
    Electronic Circuit Breaker
    Current Sensors
    Motor Speed Controllers

    Specifications:
    1) Basic Primary Current (Ib) : 10 Amp.
    2) Maximum Primary Current (Imax) : 80 Amp. 3) Secondary Current : 32 mA.
    4) Winding Ratio : 1:2500
    5) Frequency : 50 Hz
    6) Accuracy Class : 1.0
    7) Recommended Burden Resistance (Ru) : 25 Ohms @ Vout = 0.8 Volts. Maximum Value: 817 Ohms. (As per Eqn. R = Vct X N / Ip )*.
    8) Recommended Burden Resistance (Ra) : Maximum Value: 1702 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
    9) Insulation – Pri & Sec : 5000V
    10) Insulation – Pri,Sec & Earth : ≥ 1000 M
    11) Operating & Storage Temp. : -40C ~ +85C
    12) Humidity : ≤90%
    13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
    14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 25.5 X 39 X 19 / (With Dabbi)- 9 X 39 X 22

    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.


    Additional Information:

  • Item Code: SET2X3106-2500-80A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    100 Amp. Current Transformer

    REQUEST CALLBACK

    100 Amp. Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity100 Unit
    Accuracy Class1
    CT Ratio1:550
    Rated Power (VA) 2.6Watt
    Rated Voltage230VAC

    Features :

    Designed and developed as per European Standards IEC : 62053-21 / IS: 13779

    Current Transformer with PC Housing for better insulation and environmental protection.

    Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications:

    • Energy Meters
    • Electronic Circuit Breaker
    • Current Sensors
    • Motor Speed Controllers

    Specifications:

    1) Basic Primary Current (Ib) : 10 Amp.

    2) Maximum Primary Current (Imax) : 100 Amp.

    3) Secondary Current : 40 mA.

    4) Winding Ratio : 1:2500

    5) Frequency : 50 Hz

    6) Accuracy Class : 1.0

    7) Recommended Burden Resistance (Ru) : 25 Ohms @ Vout = 1 Volts. Maximum Value: 1500 Ohms. (As per Eqn. R = Vct X N / Ip )*.

    8) Recommended Burden Resistance (Ra) : Maximum Value: 3500 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.

    9) Insulation – Pri & Sec : 5000V

    10) Insulation – Pri,Sec & Earth : ≥ 1000 M

    11) Operating & Storage Temp. : -40C ~ +85C

    12) Humidity : ≤90%

    13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi

    14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 10.2 X 28.5 X 23.5

     

    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter.

    Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly

    select at your discretion.


    Additional Information:

  • Item Code: SET2x2610-2500-100A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    200 Amp. Current Transformer

    REQUEST CALLBACK

    200 Amp. Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity100 Unit
    Accuracy Class 1.0
    Accuracy Class1 or 3
    CT Ratio1:6000

    Features :
    Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
    Current Transformer with PC Housing for better insulation and environmental protection.
    Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications:
    Energy Meters
    Electronic Circuit Breaker
    Current Sensors
    Motor Speed Controllers

    Specifications:
    1) Basic Primary Current (Ib) : 10 Amp.
    2) Maximum Primary Current (Imax) : 200 Amp.
    3) Secondary Current : 33.3 mA.
    4) Winding Ratio : 1:6000
    5) Frequency : 50 Hz
    6) Accuracy Class : 1.0
    7) Recommended Burden Resistance (Ru) : 30 Ohms @ Vout = 1 Volts. Maximum Value: 1571 Ohms. (As per Eqn. R = Vct X N / Ip )*.
    8) Recommended Burden Resistance (Ra) : Maximum Value: 3273 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
    9) Insulation – Pri & Sec : 5000V
    10) Insulation – Pri,Sec & Earth : ≥ 1000 M
    11) Operating & Storage Temp. : -40C ~ +85C
    12) Humidity : ≤90%
    13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi
    14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 32.5 X 64 X 24
    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.

    Additional Information:

  • Item Code: SET5811-5000-200A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    300 AMP. Current Transformer

    REQUEST CALLBACK

    300 AMP. Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity100 Unit
    Accuracy Class1 or 3
    CT Ratio1:2000

    Features :
    Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
    Current Transformer with PC Housing for better insulation and environmental protection.
    Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications:
    Energy Meters
    Electronic Circuit Breaker
    Current Sensors
    Motor Speed Controllers

    Specifications:
    1) Basic Primary Current (Ib) : 10 Amp.
    2) Maximum Primary Current (Imax) : 300 Amp.
    3) Secondary Current : 150 mA.
    4) Winding Ratio : 1:2000
    5) Frequency : 50 Hz
    6) Accuracy Class : 1.0
    7) Recommended Burden Resistance (Ru) : 6 Ohms @ Vout = 0.9 Volts. Maximum Value: 283 Ohms. (As per Eqn. R = Vct X N / Ip )*.
    8) Recommended Burden Resistance (Ra) : Maximum Value: 590 Ohms. For Analog Interface using bridge rectifier and bulk capacitor.
    9) Insulation – Pri & Sec : 5000V
    10) Insulation – Pri,Sec & Earth : ≥ 1000 M
    11) Operating & Storage Temp. : -40C ~ +85C
    12) Humidity : ≤90%
    13) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi
    14) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 22.5 X 48.5 X 15.5 / (With Dabbi)- 54.5 X 62 X 20

    *Here Vct is considered as the CT secondary voltage signal required to feed the AtoD converter of uC and it is assumed to be less than absolute maximum rating of input pin of AtoD converter. Kindly keep Vct = Vout below 1 Volts for accurate reading this implies that lower value of burden resistance helps increase accuracy. Using higher bit ADC increases the precision level. Kindly select at your discretion.


    Additional Information:

  • Item Code: SET4511-2000-300A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    View PDF

    30 AMP ELCB / RCCB / RCD Current Transformer

    REQUEST CALLBACK

    30 AMP ELCB / RCCB / RCD Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity100 Unit
    Core TypeBar CT, Ring Core Type CT

    Features :
    Designed and developed as per European Standards IEC : 62053-21 / IS: 13779
    Current Transformer with PC Housing for better insulation and environmental protection.
    Variants available in Self Wire (Flying Leads) or PCB Mounting Type CT.

    Applications:
    Energy Meters
    Electronic Circuit Breaker
    Residual Current Circuit Breakers
    Earth Leakage Current Circuit Breaker
    Current Sensors
    Motor Speed Controllers

    Specifications:
    1) Maximum Primary Current (IL , IN) : 30 Amp.
    2) Winding Ratio : 1:525
    3) Frequency : 50 Hz
    4) Accuracy Class : 1.0
    5) Sensitivity ( Ir ) : 7 mA.
    6) Insulation – Pri & Sec : 5000V
    7) Insulation – Pri,Sec & Earth : ≥ 1000 M
    8) Operating & Storage Temp. : -40C ~ +85C
    9) Humidity : ≤90%
    10) Mounting Type / Housing (Optional) : Self (Flying) Wire-Without Dabbi / Self (Flying) Wire-With Dabbi / PCB Mounting-With Dabbi.
    11) Dimensions ( I.D. X O.D. X H in mm.) : (Without Dabbi)- 7.7 X 29 X 18.3 / (With Dabbi)- 30.5 X 34.5 X 21.7


    Additional Information:

  • Item Code: SET2615-525-30A
  • Production Capacity: 500000 per month
  • Yes! I am Interested

    Current Transformer

    REQUEST CALLBACK

    Current Transformer
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity50 Unit
    Accuracy Class 1.0
    Accuracy Class1 or 3
    CT Ratio1:6000

    A company with ISO - 9001 : 2008 Certified Production Process.

     

    We support our customers to achieve best quality and performance with our high grade ferrite winding products.

     

    All products Designed and Manufactured as per Customers Requirement with state of the art automatic winding machinery and cutting edge testing setup with Automatic Testing Equipments.

     

    The Current Transformer Coils, we manufacture are designed using latest technology and optimum quality raw material. These Current Sensing coils are available in different technical specifications and test details.

    • Phase angle
    • Minimum amplitude error
    • Liner linearity
    • Magnetic stability
    • No saturation condition
    • International meter standards
    • Shah electronics manufactures the C.T.s from 5 AMP to 200 AMP
    • Capacity with accuracy of class 0.5 & 0.2.

    Applications:-

    • Digital Energy Meters
    • Motor Current Sensing
    • Instrument Transformers

    Additional Information:

  • Item Code: Current-Transformer-Coils
  • Production Capacity: 200000 pcs per month
  • Yes! I am Interested

     
    X


    Call Us: +91-8079448006
    Shah Electronics
    Hitesh Shah
    A - 3, Manoharvilla, Naroda Nikol Road New Naroda, Naroda,
    Ahmedabad - 382330, Gujarat, India
    Contact via E-mail
    Contact via SMS



    Home  |   Profile   |  Products  |  Site Map  |   Contact Us   |   Mobile Site

    © Shah Electronics. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Shah Electronics